Designed in the 80's for service well into the 21st century, the Target Corporation AN/FRN-44 VOR is the perfect marriage of sophisticated navigational electronics and computer age data processing techniques. This latest generation of NAVAIDS gives the user troublefree, all channel, all solid state VOR system that can virtually troubleshoot itself. A standard display terminal provides both graphic and verbal indications and instructions to the operator allowing quick and easy troubleshooting and repair.

The Target Corporation solid state VOR navigational system is a rugged, highly reliable, modular, all solid state equipment which has been designed to meet the newest United States Air Force VOR requirements. The VOR has full remote maintenance monitor capability and features built-in fault isolation. The system is normally supplied with the Alford Loop Antenna Array. However, a slot antenna can be provided if desirable.


FEATURES


SUPPORT SERVICES

Target Corporation maintains a staff of experienced personnel for assisting customers in the following support services:


SPECIFICATIONS

Normal Operating Temperature: 0 to + 49°C
Storage Temperature: - 40°C to + 68°C
Operating Altitude: 10, 000 ft
Input Main Power: 120 Vac at 47-63 Hz or 208 Vac, 3-phase, 4-wire at 47-63 Hz, 1200 W maximum
Weight: 400 lbs
Relative Humidity: To 95%

Transmitter
Frequency Range: 108 to 118 MHz
Frequency Stability: ±.001%
Carrier Power: 100 Waft minimum (at end of 50 ft RG214/U cable)
Power Stability: ± 0.5 dB
9960 Hz Modulation FM Stability: ±1%
1020 Hz Modulation Stability: ±1%
Output Spectrum: Exceeds ICAO, Annex 10
Full Voice Input: - 20 to 0 dBm
Voice Regulating Range: 20 dB

Goniometer
Carrier Suppression: Greater than 30 dB
Phase Tracking: ±3° maximum
Power Output: Adjustable 500 mW to 3.5 W
Carrier Power Tracking: ±.5 dB
Output Power Balance: within ±.5 dB (automatically compensated)
9960 Hz Frequency Stability: ±.01%
Frequency Deviation: ± 480 Hz ± 15 Hz
Harmonic Distortion: 1% (maximum) of recovered FM

Monitor
Fail Safe: Any Internal Monitor malfunction will cause an alarm

Modulation Alarm Limits:
Variable Component: Separate upper and lower threshold points ± 10% to ±20%
Subcarrier Component: Separate upper and lower threshold points ± 10% to ±20%
Identification Alarm Limits: Continuous or absent IDENT code
Course Alarm Limits: Presettable in 0.1° steps from ± 0.5° to ± 1.9° over range of 000.0° through 359.9°
Radiated Power Alarm Limits: Adjustable threshold for a decrease between 1 dB and 3 dB from nominal power setting
Subcarrier Frequency Deviation Alarm Limit: Adjustable deviation alarm points over a ± 56 Hz deviation
Bearing Measurement Accuracy: Repeatability of ground checks is within ± 0.3° of reference check



[